The Dhyana XV are a series of fully in-vacuum, high-speed, cooled sCMOS cameras which utilize various back-illuminated sensors without anti-reflection coating for soft X-ray and EUV direct detection. With a high-vacuum-seal design and vacuum-compatible materials make these cameras well suited for UHV applications.

  • Reliable Invacuum Design
  • ~100% Peak QE @ 80-1000 eV
  • 10⁻6 Pa Vacuum Compatbility
  • 2Kx2K, 4Kx4K, 6Kx6K Resolution
  • USB 3.0
Quote and Query

Description

Flexible Camera Placement Possibility

Every Dhyana XV is tested in vacuum, specially including the liquid cooling, feedthroughs and electrical cables,giving  exceptional reliability within the vacuum chamber. What’s more, customization of feedthrough flange is possible.

 

 

 

Soft X-ray Energy Sensitivity

New generation back-illuminated sCMOS sensors without  antireflective coating, extend the camera capability to detect vacuum ultra violet (VUV) light, extreme ultra violet (EUV) light and soft x-ray photons with quantum efficiency approaching 100%. In addition, the sensor demonstrates excellent resistance to radiation damage in soft x-ray detection applications.

 

Varies Format Sensor Options

 

Based on the same hardware platform, The Dhyana XV series has a  range of back-illuminated sCMOS sensors with different resolutions and pixel sizes 2Kx2K, 4Kx4K, 6Kx6K.

 

 

 

High Frame Rate

Compared with conventional CCD cameras used in this market, the new sCMOS provides more than 10x higher readout speed via high-speed data interface which means saving much more time during the image acquisition.

 

 

 

Specification

Model Dhyana XV
Sensor Type BSI sCMOS
Sensor Model non anti-reflection coating
Peak QE ~100%
Spectral Range 80~1000eV, 200~1100nm
Pixel Size 6.5 x 6.5 μm/11 x 11 μm, 9 x 9 μm, 10 x 10 μm
Resolution 2048×2048, 4096×4096, 6144×6144
Array Diagonal 1.2 inch/2 inch, 3.2 inch, 5.4 inch
Effective area 13.3x 13.3 mm/22.5 x 22.5 mm, 36.9 x36.9 mm, 61.4 x 61.4 mm
Shutter Rolling
Cooling Method Water cooling
Cooling Temperature Below ambient temperature 60°C (Max)
Vacuum Compatibility 10⁻6 Pa (Max)
Trigger Mode Hardware trigger, Software trigger
Output Trigger Signals Exposure Start, simulated Global, Readout End, High level, Low Level
Trigger Interface Hirose
Data Interface filber to USB3.0 (fiber inside the vacuum)
Flange Size Feedthrough DN100CF/Customization
Software Mosaic, Samplepro, LabView, Matlab
SDK C,C++,C#
Operating System Windows, Linux
Operating Environment Temperature 0~40°C, Humidity 10~85%