SEMICONDUCTOR INSPECTION & METROLOGY

Laser Sources for Semiconductor Inspection and Metrology

Laser sources for a closer look at every wafer.

From surface defects to thin-film properties, find the wavelength, stability and beam characteristics your optical measurement demands.

Illustration of laser illumination of a patterned semiconductor wafer
ENGINEERED LIGHT. MEASURABLE INSIGHT.

SEE MORE. UNDERSTAND MORE.

Light for every layer
of understanding.

Optical inspection connects what happens on a wafer to what happens in your process. Match the light source to the measurement, the material and the signal you need to resolve.

Conceptual inspection illustration. Detection performance depends on the complete optical system.

Find a source for your technique ↘

01

Wafer defect inspection

Scan bare wafers for particles, scratches and surface contamination. Bright-field measurements track reflected light; dark-field systems collect light scattered by defects.

Consider: UV wavelength, intensity noise and beam pointing stability.

02

Patterned wafer inspection

Reveal pattern anomalies using bright-field or dark-field imaging and die-to-die comparison. Select illumination around feature contrast, optical resolution and the sample’s exposure limits.

Consider: wavelength, beam uniformity and repeatable illumination.

03

Thin-film metrology

Use laser reflectometry or laser-based ellipsometry to investigate film thickness and optical properties. Measurements combine reflected intensity or polarization with an appropriate layer model.

Consider: power stability, polarization and wavelength accuracy.

04

Interferometry

Compare light from a wafer surface with a reference to measure surface shape, flatness or displacement. Single-frequency sources support coherent measurement architectures.

Consider: coherence length, frequency stability and optical path difference.

05

Material characterization

Probe stress, crystal structure and composition with Raman spectroscopy, or investigate optical emission with photoluminescence. Excitation choice depends on the material and background fluorescence.

Consider: linewidth, excitation wavelength, filtering and sample heating.

THE FUNDAMENTALS

How wafer and reticle
inspection works.

Inspection locates anomalies; metrology quantifies properties such as thickness or surface shape. Both turn an optical signal into information about a sample, but the illumination and analysis depend on what is being measured.

From illumination to a defect map

A typical optical inspection system illuminates the sample, collects reflected, transmitted or scattered light, and records the signal with a detector. Scanning or imaging associates that signal with a position. Analysis then separates likely defects from the expected background for review.

  1. 01 Illuminate
  2. 02 Collect light
  3. 03 Compare signals
  4. 04 Map & review

BARE / UNPATTERNED WAFERS

Find defects before they become part of the process.

Bare-wafer inspection looks for particles, scratches, pits and contamination without a circuit pattern in the background. A common approach combines wafer rotation with radial laser scanning, recording changes in scattered or reflected light to build a position-based defect map.

Incoming inspection establishes a starting condition. Comparing measurements before and after a process can help identify contamination introduced by that process.

PATTERNED WAFERS

Separate unexpected features from intentional patterns.

Circuit structures create their own optical contrast and scattering. Patterned-wafer systems therefore compare aligned images of equivalent dies or repeating cells. After compensating for normal variation, differences can flag particles, missing features or possible bridges and breaks for review.

The reference matters: a defect repeated in both test and reference images may be missed by a simple subtraction. Detection also depends on alignment, contrast and the inspection recipe.

Two complementary ways to collect light

Bright-field and dark-field describe the collection geometry, rather than a particular laser model.

Bright-field inspection: the detector collects the main reflected beam from the wafer

Bright-field: inspect the main return

The detector receives the specular reflection. Defects can appear as changes in that bright background. This geometry is useful when the feature of interest produces measurable reflected-intensity or image contrast.

Dark-field inspection: the main reflection is excluded and a detector collects light scattered by a surface defect

Dark-field: isolate the scattered light

The main reflection is kept out of the detection path. Light scattered by a particle or surface irregularity stands out against a darker background. Roughness and intentional patterns can also scatter light, so background rejection is essential.

Simplified reflection geometries for explanation; angles and collection paths vary by instrument.

RETICLE / PHOTOMASK INSPECTION

Inspect the pattern that prints the wafer.

A reticle carries the pattern transferred during lithography. A printable defect can recur across many exposures, making reticle qualification and periodic inspection important alongside wafer inspection.

For transmissive optical masks, transmitted-light imaging reveals changes in transparent and opaque regions; reflected-light inspection adds surface and contamination information. Inspection can cover mask blanks, patterned surfaces and protective pellicles, with different recipes for each.

Die-to-die comparison

Compare equivalent patterned regions on the same reticle to locate unexpected differences.

Die-to-database comparison

Compare the acquired image with a reference generated from design data, using a model appropriate to the mask and imaging system.

Reflective EUV masks

EUV masks use reflective multilayers. Actinic inspection uses the lithography wavelength, 13.5 nm, to assess defects whose printing behavior may differ from their appearance at longer wavelengths. It requires specialized EUV instrumentation.

Where metrology adds another dimension

Interferometry converts phase differences between sample and reference light into surface-shape information. Reflectometry and ellipsometry infer film properties from intensity or polarization changes through an optical model. Raman and photoluminescence measurements add information about material structure and optical response.

For laser-based implementations, choose power, noise, coherence and wavelength around the complete measurement. The catalog candidates below cover selected UV, visible and near-IR techniques; their specifications do not establish reticle qualification or actinic EUV capability.

Explore sources for your measurement ↓

Technical background: Newport inspection fundamentals · KLA reticle qualification · Lasertec actinic inspection · HÜBNER optical metrology

START WITH THE RIGHT SOURCE

Explore the laser shortlist.

Selected models from the Aladdin Optics catalog. Filter by technique to explore candidates, then discuss your operating conditions with our team.

Showing 4 laser sources

Specifications reflect published product listings checked November 2, 2026. Options vary by configuration; confirm final specifications and suitability before ordering. Application matches are selection guidance, not validated inspection-system performance.

Browse the full laser portfolio ↗

FROM REQUIREMENT TO RECOMMENDATION

Specify the signal.
We’ll help select the source.

A wavelength is only the beginning. Share these parameters so we can discuss a source that fits your measurement architecture.

01 / OPTICAL

What are you measuring?

Wafer material, film stack, defect type, technique and required signal contrast.

02 / SOURCE

What does the signal need?

Wavelength, power at the sample, noise bandwidth, linewidth, polarization and beam quality.

03 / INTEGRATION

How will it fit?

Free-space or fiber delivery, modulation, footprint, cooling, environment and project timeline.

Common selection questions

Does a shorter wavelength always improve inspection?

Shorter wavelengths can support smaller diffraction-limited spots, but sensitivity also depends on scattering, material absorption, optical collection, detector response and signal processing. Evaluate the complete system and sample exposure limits.

When should I choose a single-frequency laser?

Consider a single-frequency source for measurements that require stable phase relationships or a long coherence length. Confirm frequency drift and coherence against the interferometer’s path difference and measurement time.

Which source should I choose for Raman characterization?

532 nm and 785 nm are candidates with different tradeoffs in Raman signal strength, fluorescence background and detector response. Match linewidth to the spectral resolution required, and confirm power density to limit sample heating.